Measurement technique for classifying aerosol particles
A Particle mass analyser(PMA) is an instrument for classifying aerosol particles according to their mass-to-charge ratio using opposing electrical and centrifugal forces. This allows the classifier to select particles of a specified mass-to-charge ratio independent of particle shape.[1]
It one of the three types of monodisperse aerosol classifier, the others being the differential mobility analyser (DMA, for electrical mobility size), and the aerodynamic aerosol classifier (AAC, for relaxation time, or aerodynamic diameter). The corresponding three quantities are related by the expression τ = mB, where τ is relaxation time, m is mass and B is mobility.
Further work improved the technique by engineering the centrifugal force to match the electrostatic force across the whole classification region, thus increasing the throughput.[2]
^Ehara; et al. (March 1996). "Novel method to classify aerosol particles according to their mass-to-charge ratio - Aerosol particle mass analyser" (PDF). Journal of Aerosol Science. 27 (2): 217. Bibcode:1996JAerS..27..217E. doi:10.1016/0021-8502(95)00562-5.
^Olfert and Collings (Nov 2005). "New method for particle mass classification—the Couette centrifugal particle mass analyzer". Journal of Aerosol Science. 36 (11): 1336. Bibcode:2005JAerS..36.1338O. doi:10.1016/j.jaerosci.2005.03.006.
and 23 Related for: Particle mass analyser information
A Particlemassanalyser (PMA) is an instrument for classifying aerosol particles according to their mass-to-charge ratio using opposing electrical and...
teams, proposed the Higgs mechanism, a way for some particles to acquire mass. (All fundamental particles known at the time should be massless at very high...
data from particle counters distributed globally gives trend information to the state of quality of air and its migration. Particlemassanalyser Particulate...
charged particles of different specific charges", published 1960-06-07, assigned to Wolfgang Paul de Hoffmann, Edmond; Vincent Stroobant (2003). Mass Spectrometry:...
of the energy–momentum of a perfect fluid. Although no particles are known to have negative mass, physicists (primarily Hermann Bondi in 1957, William...
difference is that molecular mass is the mass of one specific particle or molecule, while the molar mass is an average over many particles or molecules. The formula...
function of the mass-to-charge ratio. These spectra are used to determine the elemental or isotopic signature of a sample, the masses of particles and of molecules...
Aerosol mass spectrometry is the application of mass spectrometry to the analysis of the composition of aerosol particles. Aerosol particles are defined...
defined as the mass of the many particles of the material divided by the bulk volume. Bulk volume is defined as the total volume the particles occupy, including...
mass spectrum, but the experiments did not confirm the existence of the hypothetical particle in an August 2016 report. In July 2017, many analyses based...
^{3}\;\mathrm {s} ^{-1}} , which is roughly what is expected for a new particle in the 100 GeV mass range that interacts via the electroweak force. Experimental...
The mass of the sample of each sieve is then divided by the total mass to give a percentage retained on each sieve. The size of the average particle on...
In grammar, the term particle (abbreviated PTCL) has a traditional meaning, as a part of speech that cannot be inflected, and a modern meaning, as a function...
Hussain, R., Noyan, M. A., Woyessa, G. et al. An ultra-compact particle size analyser using a CMOS image sensor and machine learning. Light Sci Appl 9...
lipstick brand and color. Single Particle Inductively Coupled Plasma Mass Spectroscopy (SP ICP-MS) was designed for particle suspensions in 2000 by Claude...
symmetry between particles with integer spin (bosons) and particles with half-integer spin (fermions). It proposes that for every known particle, there exists...
engineering and environmental analyses. For example, mass balance theory is used to design chemical reactors, to analyse alternative processes to produce...
and the secondary ion extraction lens, (4) a massanalyser separating the ions according to their mass-to-charge ratio, and (5) a detector. SIMS requires...
each particle in the bottom stream has a larger mass energy than a particle in the top. (2) Because of Lorentz contraction, there are more particles per...
nucléaire), is an intergovernmental organization that operates the largest particle physics laboratory in the world. Established in 1954, it is based in Meyrin...