Contrast resolution is the ability to distinguish between differences in intensity in an image.[1] The measure is used in medical imaging to quantify the quality of acquired images. It is a difficult quantity to define because it depends on the human observer as much as the quality of the actual image. For example, the size of a feature affects how easily it is detected by the observer.[2]
One definition of image contrast is:
where SA and SB are signal intensities for signal-producing structures A and B in the region of interest.[3] A disadvantage of this definition is that the contrast C can be negative. An alternative definition is:
where Sref is a reference signal intensity, which is independent of the type of signal-producing structure under investigation.[4]
In MRI, determining contrast is of high importance for calibration because the operator has a high degree of control of how the signal intensities of various structures vary in the images by using different MRI methods and imaging parameters. Unlike most other imaging modalities, such as x-ray CT in which the Hounsfield units value for water is set to zero, there is no standard reference signal for MRI. Thus the contrast-to-noise ratio is often employed as an index for contrast because this metric does not require a reference signal.
Contrast resolution or contrast-detail is an approach to describing the image quality in terms of both the image contrast and resolution.
Contrast resolution is usually measured by generating a pattern from a test object that depicts how image contrast changes as the structures being imaged get smaller and closer together. The picture below shows one such set of images produced using the low contrast detectability inserts of the phantom employed in the MRI accreditation program of the American College of Radiology.
^The encyclopaedia of medical imaging. ISBN 1-901865-13-4.
^Oppelt, Arnulf (13 January 2006). Imaging Systems for Medical Diagnostics: Fundamentals, Technical Solutions and Applications for Systems Applying Ionizing Radiation, Nuclear Magnetic Resonance and Ultrasound. John Wiley & Sons. p. 44. ISBN 3-89578-226-2.
^Hendrick, R. E.; Raff, U. (1992). Stark, David D.; Bradley, William G. (eds.). Magnetic Resonance Imaging (2nd ed.). St. Louis: Mosby. pp. 109–144.
^Edelstein, W. A.; Bottomley, P. A.; Hart, H. R.; Smith, L. S. (1983). "Signal, noise and contrast in nuclear magnetic resonance (NMR) imaging". Journal of Computer Assisted Tomography. 7 (3): 391–401. doi:10.1097/00004728-198306000-00001. PMID 6841698. S2CID 20194169.
and 23 Related for: Contrast resolution information
Contrastresolution is the ability to distinguish between differences in intensity in an image. The measure is used in medical imaging to quantify the...
with similar impedances and thus lead to higher contrastresolution." Along with higher contrastresolution it has an elevated signal-to-noise ratio and...
The display resolution or display modes of a digital television, computer monitor, or other display device is the number of distinct pixels in each dimension...
This contrast transfer function (CTF) sets the resolution of high-resolution transmission electron microscopy (HRTEM), also known as phase contrast TEM...
observed from above. Limitations include low contrast of most biological samples and low apparent resolution due to the blur of out-of-focus material. The...
Differential interference contrast (DIC) microscopy, also known as Nomarski interference contrast (NIC) or Nomarski microscopy, is an optical microscopy...
allows pharmacokinetic (PK) modelling of contrast agent but can limit possible image resolution. Slower time resolution allows more detailed images, but may...
quantity of scattered x-rays that reach the detector. This improves the contrastresolution of the image, but also increases radiation exposure for the patient...
weaker contrast. Crystal structure can also be investigated by high-resolution transmission electron microscopy (HRTEM), also known as phase contrast. When...
of Airy discs, which assumes an adequate level of contrast. In low-contrast systems, the resolution may be much lower than predicted by the theory outlined...
of 16:9, implying a resolution of 2.1 megapixels. It is often marketed as Full HD or FHD, to contrast 1080p with 720p resolution screens. Although 1080p...
types of soft tissue. This is possible with MRI's higher spatial and contrastresolution. Overall, it is estimated that MRI has a sensitivity of 74% and specificity...
provide higher spatial resolution, CT can detect more subtle variations in attenuation of X-rays (higher contrastresolution). CT exposes the patient...
A display resolution standard is a commonly used width and height dimension (display resolution) of an electronic visual display device, measured in pixels...
staging and follow-up of disease. Compared to CT, MRI provides better contrast in images of soft tissues, e.g. in the brain or abdomen. However, it may...
4K resolution refers to a horizontal display resolution of approximately 4,000 pixels. Digital television and digital cinematography commonly use several...
The largest element observed without distinct image contrast indicates the approximate resolution limit.[citation needed] This element's label is noted...
format, which has a resolution of 1280×720p. The number 720 stands for the 720 horizontal scan lines of image display resolution (also known as 720 pixels...
Biermann, H (2015). "Case studies on the application of high resolution electron channelling contrast imaging–investigation of defects and defect arrangements...
cells in the abdomen due to the poor spatial resolution amongst soft-tissue densities. Contrastresolution obtained through CT allows radiologists to investigate...
the Catalyst Control Centre, which enables control of brightness, contrast, resolution etc., and also enables connection to an external display the best...
optical scattering, photoacoustic microscopy is capable of achieving high-resolution images at greater depths than conventional microscopy methods. Furthermore...
therefore muography can be used worldwide. Second, because of the high-contrastresolution of muography, a small void of less than 0.001% of the entire volume...