estimate of amniotic fluid and an indicator of fetal well-being
Amniotic fluid index (AFI) is a quantitative estimate of amniotic fluid[1] and an indicator of fetal well-being. It is a separate measurement from the biophysical profile.[1]
AFI is the score (expressed in centimetres) given to the amount of amniotic fluid seen on ultrasonography of a pregnant uterus. To determine the AFI, doctors may use a four-quadrant technique,[2] when the deepest, unobstructed, vertical length of each pocket of fluid is measured in each quadrant and then added up to the others,[3] or the so-called "single deepest pocket" technique.[4]
An AFI between 8 and 18 cm is considered normal.[5] Median AFI level is approximately 14 cm from week 20 to week 35,[6] when the amniotic fluid begins to reduce in preparation for birth. An AFI smaller than 5–6 cm is considered as oligohydramnios.[3] The exact number can vary by gestational age. The fifth percentile for gestational age is sometimes used as a cutoff value.[7]
An AFI larger than 24–25 cm is considered as polyhydramnios.[3][8]
^ abTom C Winter; Sanders, Roger C. (2006). Clinical Sonography: A Practical Guide. Hagerstown, MD: Lippincott Williams & Wilkins. p. 502. ISBN 0-7817-4869-0.
^ abcCarr, Phyllis L.; Ricciotti, Hope; Freund, Karen M.; Scott Kahan (2003). In a Page Ob/Gyn & Women's Health (In a Page). Cambridge, MA: Blackwell Publishers. p. 105. ISBN 1-4051-0380-9.
^"Los Bajos Niveles de Líquido Amniótico: Oligohidramnios". 2012-04-27.
^"Amniotic Fluid Index". Archived from the original on 2019-02-04.
^Griffin M, Attilakos G, Greenwood R, Denbow M (2009). "Amniotic fluid index in low-risk, post-dates pregnancies". Fetal Diagn. Ther. 26 (4): 212–5. doi:10.1159/000265554. PMID 20029220. S2CID 33665604.
^Sylvia Dobo; Mitchell King; Lipsky, Martin S.; Jeff Susman (2003). Family Medicine Certification Review. Cambridge, MA: Blackwell Publishers. p. 133. ISBN 1-4051-0329-9.
and 27 Related for: Amniotic fluid index information
Amnioticfluidindex (AFI) is a quantitative estimate of amnioticfluid and an indicator of fetal well-being. It is a separate measurement from the biophysical...
excess of amnioticfluid in the amniotic sac. It is seen in about 1% of pregnancies. It is typically diagnosed when the amnioticfluidindex (AFI) is greater...
amniotic fluidindex (AFI) measures less than 5 cm or when the single deepest pocket (SDP) of amnioticfluid measures less than 2 cm. Amnioticfluid is necessary...
indications. The "modified biophysical profile" consists of the NST and amnioticfluidindex only. The BPP has five components: four ultrasound (US) assessments...
fluid within the amnion is called amnioticfluid, and because this fluid surrounds the developing fetus, it contains fetal cells. The amnioticfluid is...
is an abnormally low or complete absence of amnioticfluid surrounding the fetus in the womb. Amnioticfluid is a clear, watery substance that surrounds...
Football Israel, a nonprofit sports organization Amnioticfluidindex, a measure of the amount of amnioticfluid of a fetus Aniridia Foundation International...
Pooling test: visualization of amnioticfluid pooling in the vagina Nitrazine paper test Fern test Amnioticfluidindex For results to be roughly 90% accurate...
increase the amnioticfluidindex to over 5 cm. Amnioinfusion can also be performed transcervically (through the cervix) after the amniotic sac has ruptured...
other manifestation of this syndrome. The constriction of appendages by amniotic bands may result in:[citation needed] Constriction rings around the digits...
fetal head, a non-engaged breech, non-anterior placenta, and an amnioticfluidindex above 7–10 cm, are all factors which can be associated with higher...
and, therefore, contacts the amnioticfluid, the fetus and the umbilical cord. The internal pressure of the amnioticfluid causes the amnion to be passively...
rupture of membranes. Amnioticfluid typically has a pH > 7.2, bromothymol will therefore turn blue when brought in contact with fluid leaking from the amnion...
cited, and has failed to be replicated. The level of estrogen in the amnioticfluid is not correlated with higher 2D:4D, as researchers found no difference...
believed it to be present in the amnioticfluid. In 1821, the French chemist Jean Louis Lassaigne found it in the fluid of the allantois; he called it "l'acide...
in amnioticfluid and umbilical cord blood. These stem cells are very active, expand extensively without feeders and are not tumorigenic. Amniotic stem...
stem cell research involves human embryos. For example, adult stem cells, amniotic stem cells, and induced pluripotent stem cells do not involve creating...
index finger into the opening of the cervix or neck of the womb. They then use a circular movement to try to separate the membranes of the amniotic sac...
vitro expanded corneal limbal stem cells are found to be effective as amniotic membrane based expansion is controversial. For endothelial diseases, such...
levels decrease, PGF2 levels will peak. When injected into the body or amniotic sac, PGF2α can either induce labor or cause an abortion depending on the...
being used for respiration at this point as the fetus is suspended in amnioticfluid). 3D ultrasound of 80-millimetre (3 in) fetus (about 3+1⁄2 months gestational...
predictor kits (OPKs), and microscopic examination of saliva or cervical fluid. Also available are computerized fertility monitors. Symptoms-based methods...
small proportion of cases are due to the embolization of air, fat, or amnioticfluid. Diagnosis is based on signs and symptoms in combination with test results...
placenta, including site of umbilical cord insertion when possible Amnioticfluid volume Gestational age assessment Fetal weight estimation Fetal anatomical...
peripheral circulation.[citation needed] Extracting stem cells from amnioticfluid is possible for both autologous and heterologous uses at the time of...
of the late complication meconium peritonitis. Before birth, excess amnioticfluid (polyhydramnios) is a possible symptom. This is more common in duodenal...