Global Information Lookup Global Information

Thermal ionization mass spectrometry information


Thermal ionization mass spectrometer. Vacuum chamber on the left, electromagnet in the center, and ions detector on the right are visible.

Thermal ionization mass spectrometry (TIMS) is also known as surface ionization and is a highly sensitive isotope mass spectrometry characterization technique. The isotopic ratios of radionuclides are used to get an accurate measurement for the elemental analysis of a sample.[1] Singly charged ions of the sample are formed by the thermal ionization effect. A chemically purified liquid sample is placed on a metal filament which is then heated to evaporate the solvent. The removal of an electron from the purified sample is consequently achieved by heating the filament enough to release an electron, which then ionizes the atoms of the sample.[2] TIMS utilizes a magnetic sector mass analyzer to separate the ions based on their mass to charge ratio. The ions gain velocity by an electrical potential gradient and are focused into a beam by electrostatic lenses. The ion beam then passes through the magnetic field of the electromagnet where it is partitioned into separate ion beams based on the ion's mass/charge ratio. These mass-resolved beams are directed into a detector where it is converted into voltage. The voltage detected is then used to calculate the isotopic ratio.[3]

  1. ^ Becker, Johanna Sabine (30 August 2012). "Chapter 13 Inorganic Mass Spectrometry of Radionuclides". In L'Annunziata, Micheal F. (ed.). Handbook of radioactivity analysis (3rd ed.). Elsevier Science. p. 833-870. ISBN 978-0-12-384873-4.
  2. ^ A Handbook of Silicate Rock Analysis. ISBN 978-94-015-3990-6.
  3. ^ Constantinos A. Georgiou; Georgios P. Danezis. "chapter 3- Elemental and Isotopic Mass Spectrometry". In Pico, Yolanda (ed.). Advanced mass spectrometry for food safety and quality (68 ed.). p. 131-243. ISBN 978-0-444-63340-8.

and 20 Related for: Thermal ionization mass spectrometry information

Request time (Page generated in 1.06 seconds.)

Thermal ionization mass spectrometry

Last Update:

Thermal ionization mass spectrometry (TIMS) is also known as surface ionization and is a highly sensitive isotope mass spectrometry characterization technique...

Word Count : 1058

Inductively coupled plasma mass spectrometry

Last Update:

with other types of mass spectrometry, such as thermal ionization mass spectrometry (TIMS) and glow discharge mass spectrometry (GD-MS), ICP-MS introduces...

Word Count : 6567

Thermal ionization

Last Update:

process are ionized. Thermal ionization is used to make simple ion sources, for mass spectrometry and for generating ion beams. Thermal ionization has seen...

Word Count : 652

Mass spectrometry

Last Update:

desorption/ionization on silicon (DIOS), atmospheric pressure chemical ionization (APCI), secondary ion mass spectrometry (SIMS), spark ionization and thermal ionization...

Word Count : 10336

Electron ionization

Last Update:

was one of the first ionization techniques developed for mass spectrometry. However, this method is still a popular ionization technique. This technique...

Word Count : 4002

Ion source

Last Update:

desorption ionization mass spectrometry (PDMS), also called fission fragment ionization, is a mass spectrometry technique in which ionization of material...

Word Count : 7140

Chemical ionization

Last Update:

Chemical ionization (CI) is a soft ionization technique used in mass spectrometry. This was first introduced by Burnaby Munson and Frank H. Field in 1966...

Word Count : 2129

Monazite geochronology

Last Update:

Dilution Thermal Ionization Mass Spectrometry (ID-TIMS), (2) Secondary Ion Mass Spectrometry (SIMS), (3) Laser Ablation Inductively Coupled Plasma Mass Spectrometry...

Word Count : 7141

Fast atom bombardment

Last Update:

Fast atom bombardment (FAB) is an ionization technique used in mass spectrometry in which a beam of high energy atoms strikes a surface to create ions...

Word Count : 1811

Ambient ionization

Last Update:

Ambient ionization is a form of ionization in which ions are formed in an ion source outside the mass spectrometer without sample preparation or separation...

Word Count : 5967

Ionization

Last Update:

counter or the ionization chamber. The ionization process is widely used in a variety of equipment in fundamental science (e.g., mass spectrometry) and in medical...

Word Count : 6715

Sample preparation in mass spectrometry

Last Update:

preparation for mass spectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain...

Word Count : 5398

Nuclear forensics

Last Update:

Ideally, mass spec should offer excellent resolution/mass abundance, low backgrounds, and proper instrumental function. In thermal ionization mass spectrometry...

Word Count : 3182

Ion mobility spectrometry

Last Update:

Ion mobility spectrometry (IMS) It is a method of conducting analytical research that separates and identifies ionized molecules present in the gas phase...

Word Count : 4519

Aerosol mass spectrometry

Last Update:

Aerosol mass spectrometry is the application of mass spectrometry to the analysis of the composition of aerosol particles. Aerosol particles are defined...

Word Count : 3454

Detrital zircon geochronology

Last Update:

ion mass spectrometry (SIMS) and laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) are used instead of thermal ionization mass spectrometry...

Word Count : 3279

Electron capture ionization

Last Update:

with chemical ionization. Electron-capture mass spectrometry (EC-MS) is a type of mass spectrometry that uses electron capture ionization to form negative...

Word Count : 1116

Boron

Last Update:

analysis of natural fresh and saline waters by negative thermal ionization mass spectrometry". Chemical Geology. 143 (3–4): 255–261. Bibcode:1997ChGeo...

Word Count : 12785

TIMS

Last Update:

International Molinological Society Thermal ionization mass spectrometry Thermal infrared multispectral scanner; see Thermal infrared spectroscopy The Institute...

Word Count : 106

Field desorption

Last Update:

also the first ionization method to ionize nonvolatile and thermally labile compounds. One major difference of FD with other ionization methods is that...

Word Count : 1904

PDF Search Engine © AllGlobal.net