Thermal ionization mass spectrometry (TIMS) is also known as surface ionization and is a highly sensitive isotope mass spectrometry characterization technique. The isotopic ratios of radionuclides are used to get an accurate measurement for the elemental analysis of a sample.[1] Singly charged ions of the sample are formed by the thermal ionization effect. A chemically purified liquid sample is placed on a metal filament which is then heated to evaporate the solvent. The removal of an electron from the purified sample is consequently achieved by heating the filament enough to release an electron, which then ionizes the atoms of the sample.[2] TIMS utilizes a magnetic sector mass analyzer to separate the ions based on their mass to charge ratio. The ions gain velocity by an electrical potential gradient and are focused into a beam by electrostatic lenses. The ion beam then passes through the magnetic field of the electromagnet where it is partitioned into separate ion beams based on the ion's mass/charge ratio. These mass-resolved beams are directed into a detector where it is converted into voltage. The voltage detected is then used to calculate the isotopic ratio.[3]
^Becker, Johanna Sabine (30 August 2012). "Chapter 13 Inorganic Mass Spectrometry of Radionuclides". In L'Annunziata, Micheal F. (ed.). Handbook of radioactivity analysis (3rd ed.). Elsevier Science. p. 833-870. ISBN 978-0-12-384873-4.
^A Handbook of Silicate Rock Analysis. ISBN 978-94-015-3990-6.
^Constantinos A. Georgiou; Georgios P. Danezis. "chapter 3- Elemental and Isotopic Mass Spectrometry". In Pico, Yolanda (ed.). Advanced mass spectrometry for food safety and quality (68 ed.). p. 131-243. ISBN 978-0-444-63340-8.
and 20 Related for: Thermal ionization mass spectrometry information
Thermalionizationmassspectrometry (TIMS) is also known as surface ionization and is a highly sensitive isotope massspectrometry characterization technique...
with other types of massspectrometry, such as thermalionizationmassspectrometry (TIMS) and glow discharge massspectrometry (GD-MS), ICP-MS introduces...
process are ionized. Thermalionization is used to make simple ion sources, for massspectrometry and for generating ion beams. Thermalionization has seen...
desorption/ionization on silicon (DIOS), atmospheric pressure chemical ionization (APCI), secondary ion massspectrometry (SIMS), spark ionization and thermal ionization...
was one of the first ionization techniques developed for massspectrometry. However, this method is still a popular ionization technique. This technique...
desorption ionizationmassspectrometry (PDMS), also called fission fragment ionization, is a massspectrometry technique in which ionization of material...
Chemical ionization (CI) is a soft ionization technique used in massspectrometry. This was first introduced by Burnaby Munson and Frank H. Field in 1966...
Fast atom bombardment (FAB) is an ionization technique used in massspectrometry in which a beam of high energy atoms strikes a surface to create ions...
Ambient ionization is a form of ionization in which ions are formed in an ion source outside the mass spectrometer without sample preparation or separation...
counter or the ionization chamber. The ionization process is widely used in a variety of equipment in fundamental science (e.g., massspectrometry) and in medical...
preparation for massspectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain...
Ideally, mass spec should offer excellent resolution/mass abundance, low backgrounds, and proper instrumental function. In thermalionizationmass spectrometry...
Ion mobility spectrometry (IMS) It is a method of conducting analytical research that separates and identifies ionized molecules present in the gas phase...
Aerosol massspectrometry is the application of massspectrometry to the analysis of the composition of aerosol particles. Aerosol particles are defined...
ion massspectrometry (SIMS) and laser ablation-inductively coupled plasma massspectrometry (LA-ICPMS) are used instead of thermalionizationmass spectrometry...
with chemical ionization. Electron-capture massspectrometry (EC-MS) is a type of massspectrometry that uses electron capture ionization to form negative...
International Molinological Society ThermalionizationmassspectrometryThermal infrared multispectral scanner; see Thermal infrared spectroscopy The Institute...
also the first ionization method to ionize nonvolatile and thermally labile compounds. One major difference of FD with other ionization methods is that...