Process tomography[2] consists of tomographic imaging of systems, such as process pipes in industry. In tomography the 3D distribution of some physical quantity in the object is determined. There is a widespread need to get tomographic information about process. This information can be used, for example, in the design and control of processes.
[3]
Tomography involves taking measurements around the periphery of an object (e.g. process vessel or patient) to determine what is going on inside.
The best known technique is CT scanning in medicine; however, process tomography instrumentation needs to be cheaper, faster and more robust.
Many different imaging methods are used in process tomography, e.g. ultrasonic imaging, positron emission tomography (PET), electrical resistance tomography (ERT) and electrical impedance tomography (EIT), electrical capacitance tomography (ECT), magnetic induction tomography (MIT). In all cases external sensors are used to detect signals from boundary of the object, and the three-dimensional material distribution or the velocity field is computed using the measured data.
Williams, R. A.; Beck, M. S. (1995). Process Tomography: Principles, Techniques, and Applications. Butterworth-Heinemann. ISBN 0750607440.
Process tomography is an area of rapid growth both in terms of research and applications. There are number of challenges remaining in this area including data processing an image reconstruction,[4] and application of imaging modalities in a real applications.
^Wanta, Damian; Smolik, Waldemar T.; Kryszyn, Jacek; Wróblewski, Przemysław; Midura, Mateusz (2022). "A Run-Time Reconfiguration Method for an FPGA-Based Electrical Capacitance Tomography System". Electronics. 11 (4): 545. doi:10.3390/electronics11040545.
^ York, T., 2001. Status of electrical tomography in industrial applications, Journal of Electronic Imaging
^Gladden, L. F. (1997). "Process Tomography: Principles, Techniques and Applications". Measurement Science and Technology. 8 (4). doi:10.1088/0957-0233/8/4/021. S2CID 250815245.
^Soleimani, M., 2008. Computational aspects of low frequency electrical and electromagnetic tomography: A review study. International Journal of Numerical Analysis and Modeling, 5 (3), pp. 407–440.
and 26 Related for: Process tomography information
Processtomography consists of tomographic imaging of systems, such as process pipes in industry. In tomography the 3D distribution of some physical quantity...
Quantum tomography or quantum state tomography is the process by which a quantum state is reconstructed using measurements on an ensemble of identical...
A computed tomography scan (CT scan; formerly called computed axial tomography scan or CAT scan) is a medical imaging technique used to obtain detailed...
Tomography is imaging by sections or sectioning that uses any kind of penetrating wave. The method is used in radiology, archaeology, biology, atmospheric...
inversion process, although solutions to tomographic inversions are non-unique. Seismic tomography is similar to medical x-ray computed tomography (CT scan)...
Industrial computed tomography (CT) scanning is any computer-aided tomographic process, usually X-ray computed tomography, that uses irradiation to produce...
Positron emission tomography (PET) is a functional imaging technique that uses radioactive substances known as radiotracers to visualize and measure changes...
reconstruction of X-ray computed tomography. The projection of an object, resulting from the tomographic measurement process at a given angle θ {\displaystyle...
Industrial process imaging, or industrial processtomography or processtomography are methods used to form an image of a cross-section of vessel or pipe...
Optical coherence tomography (OCT) is an imaging technique that uses interferometry with short-coherence-length light to obtain micrometer-level depth...
instance, in quantum processtomography, the unknown quantum process is assumed to be a quantum operation. However, not all quantum processes can be captured...
Electron tomography (ET) is a tomography technique for obtaining detailed 3D structures of sub-cellular, macro-molecular, or materials specimens. Electron...
Electrical impedance tomography (EIT) is a noninvasive type of medical imaging in which the electrical conductivity, permittivity, and impedance of a part...
The history of X-ray computed tomography dates back to at least 1917 with the mathematical theory of the Radon transform In the early 1900s an Italian...
is a close relative of electrical impedance tomography and is proposed as a method for industrial process monitoring. Although capacitance sensing methods...
assessment process, psychiatrists may employ a mental status examination; a physical examination; brain imaging such as a computerized tomography, magnetic...
such as X-ray or CT. Positron emission tomography (PET) uses coincidence detection to image functional processes. Short-lived positron emitting isotope...
Cone beam computed tomography (or CBCT, also referred to as C-arm CT, cone beam volume CT, flat panel CT or Digital Volume Tomography (DVT)) is a medical...
Computed tomography angiography (also called CT angiography or CTA) is a computed tomography technique used for angiography—the visualization of arteries...
as a quantum computation Quantum teleportation with atoms: quantum processtomography Entangled State Teleportation Fidelity of quantum teleportation through...
impedance tomography (EIT) data, in a biomedical, industrial or geophysical setting. The name was originally an acronym for Electrical Impedance Tomography and...
often utilizing many different forms of tomography together to do so. The forms of tomography combined in the process depend on what is being studied and...
ionizing radiation, which distinguishes it from computed tomography (CT) and positron emission tomography (PET) scans. MRI is a medical application of nuclear...
Computed tomography of the head uses a series of X-rays in a CT scan of the head taken from many different directions; the resulting data is transformed...
In radiography, focal plane tomography is tomography (imaging a single plane, or slice, of an object) by simultaneously moving the X-ray generator and...
is also called electromagnetic induction tomography, electromagnetic tomography (EMT), eddy current tomography, and eddy current testing. The method is...