Global Information Lookup Global Information

Optical coherence tomography information


A high-resolution spectral-domain OCT scan (3×3 mm) of a dry age-related macular degeneration eye showing geographic atrophy and drusen in macula on both cross-sectional and en face fly-through.

Optical coherence tomography (OCT) is an imaging technique that uses interferometry with short-coherence-length light to obtain micrometer-level depth resolution and uses transverse scanning of the light beam to form two- and three-dimensional images from light reflected from within biological tissue or other scattering media. Short-coherence-length light can be obtained using a superluminescent diode (SLD) with a broad spectral bandwidth or a broadly tunable laser with narrow linewidth. The first demonstration of OCT imaging (in vitro) was published by a team from MIT and Harvard Medical School in a 1991 article in the journal Science.[1] The article introduced the term "OCT" to credit its derivation from optical coherence-domain reflectometry, in which the axial resolution is based on temporal coherence.[2] The first demonstrations of in vivo OCT imaging quickly followed.[3][4][5]

The first US patents on OCT by the MIT/Harvard group described both a time-domain OCT (TD-OCT) system[6][7] and a Fourier-domain OCT (FD-OCT) system of the swept-source variety.[6] These patents were licensed by Zeiss and formed the basis of the first generations of OCT products until 2006. Tanno et al. obtained a patent on optical heterodyne tomography (similar to TD-OCT) in Japan in the same year.[8]

In the decade preceding the invention of OCT, interferometry with short-coherence-length light had been investigated for a variety of applications.[9][10][11][12][13][14][15][16][17][18][19][20]  The potential to use interferometry for imaging was proposed,[20] and measurement of retinal elevation profile and thickness had been demonstrated.[19]

The initial commercial clinical OCT systems were based on point-scanning TD-OCT technology, which primarily produced cross-sectional images due to the speed limitation (tens to thousands of axial scans per second). Fourier-domain OCT became available clinically 2006, enabling much greater image acquisition rate (tens of thousands to hundreds of thousands axial scans per second) without sacrificing signal strength. The higher speed allowed for three-dimensional imaging, which can be visualized in both en face and cross-sectional views. Novel contrasts such as angiography, elastography, and optoretinography also became possible by detecting signal change over time. Over the past three decades, the speed of commercial clinical OCT systems has increased more than 1000-fold, doubling every three years and rivaling Moore's law of computer chip performance. Development of parallel image acquisition approaches such as line-field and full-field technology may allow the performance improvement trend to continue.

OCT is most widely used in ophthalmology, in which it has transformed the diagnosis and monitoring of retinal diseases, optic nerve diseases, and corneal diseases. It has greatly improved the management of the top three causes of blindness – macular degeneration, diabetic retinopathy, and glaucoma – thereby preventing vision loss in many patients. By 2016 OCT was estimated to be used in more than 30 million imaging procedures per year worldwide.[21]

OCT angioscopy is used in the intravascular evaluation of coronary artery plaques and to guide stent placement. Beyond ophthalmology and cardiology, applications are also developing in other medical specialties such as dermatology, gastroenterology (endoscopy), neurology, oncology, and dentistry.[22][23]

  1. ^ Huang D, Swanson EA, Lin CP, Schuman JS, Stinson WG, Chang W, et al. (November 1991). "Optical coherence tomography". Science. 254 (5035): 1178–1181. Bibcode:1991Sci...254.1178H. doi:10.1126/science.1957169. PMC 4638169. PMID 1957169.
  2. ^ Youngquist RC, Carr S, Davies DE (March 1987). "Optical coherence-domain reflectometry: a new optical evaluation technique". Optics Letters. 12 (3): 158–160. Bibcode:1987OptL...12..158Y. doi:10.1364/ol.12.000158. PMID 19738824.
  3. ^ Izatt JA, Hee MR, Huang D, Fujimoto JG, Swanson EA, Lin CP, Shuman JS, Puliafito CA (1993-06-24). Parel JM, Ren Q (eds.). "Ophthalmic diagnostics using optical coherence tomography". Ophthalmic Technologies III. 1877. SPIE: 136–144. Bibcode:1993SPIE.1877..136I. doi:10.1117/12.147520. S2CID 121094027.
  4. ^ Swanson EA, Izatt JA, Hee MR, Huang D, Lin CP, Schuman JS, et al. (November 1993). "In vivo retinal imaging by optical coherence tomography". Optics Letters. 18 (21): 1864–1866. Bibcode:1993OptL...18.1864S. doi:10.1364/ol.18.001864. PMID 19829430.
  5. ^ Fercher AF, Hitzenberger CK, Drexler W, Kamp G, Sattmann H (July 1993). "In vivo optical coherence tomography". American Journal of Ophthalmology. 116 (1): 113–114. doi:10.1016/s0002-9394(14)71762-3. PMID 8328536.
  6. ^ a b US 5321501A, Swanson EA, Huang D, Fujimoto JG, Puliafito CA, "Method and apparatus for optical imaging with means for controlling the longitudinal range of the sample", issued 1994-06-14 
  7. ^ US 5459570A, Swanson EA, Huang D, Fujimoto JG, Puliafito CA, "Method and apparatus for performing optical measurements", issued 1995-10-17 
  8. ^ JA 2010042, Tanno N, Ichikawa T, Saeki A, "Lightwave Reflection Measurement", published 1990 
  9. ^ Eickhoff W, Ulrich R (November 1981). "Optical frequency domain reflectometry in single-mode fiber". Applied Physics Letters. 39 (9): 693–695. Bibcode:1981ApPhL..39..693E. doi:10.1063/1.92872. ISSN 0003-6951.
  10. ^ Gillard CW, Buholz NE (1983). "Progress In Absolute Distance Interferometry". Optical Engineering. 22 (3): 348–353. Bibcode:1983OptEn..22..348G. doi:10.1117/12.7973117. ISSN 0091-3286.
  11. ^ Fercher AF, Roth E (1986-09-15). Mueller GJ (ed.). "Ophthalmic Laser Interferometry". SPIE Proceedings. Optical Instrumentation for Biomedical Laser Applications. 0658. SPIE: 48. Bibcode:1986SPIE..658...48F. doi:10.1117/12.938523. S2CID 122883903.
  12. ^ Youngquist RC, Carr S, Davies DE (March 1987). "Optical coherence-domain reflectometry: a new optical evaluation technique". Optics Letters. 12 (3): 158–160. Bibcode:1987OptL...12..158Y. doi:10.1364/OL.12.000158. PMID 19738824.
  13. ^ Takada K, Yokohama I, Chida K, Noda J (May 1987). "New measurement system for fault location in optical waveguide devices based on an interferometric technique". Applied Optics. 26 (9): 1603–1606. Bibcode:1987ApOpt..26.1603T. doi:10.1364/AO.26.001603. PMID 20454375.
  14. ^ Kachelmyer AL (1989-02-18). Becherer RJ (ed.). "Range-Doppler Imaging Waveforms And Receiver Design". Laser Radar III. 0999. SPIE: 138–161. Bibcode:1989SPIE..999..138K. doi:10.1117/12.960231. S2CID 110631959.
  15. ^ Fercher AF, Mengedoht K, Werner W (March 1988). "Eye-length measurement by interferometry with partially coherent light". Optics Letters. 13 (3): 186–188. Bibcode:1988OptL...13..186F. doi:10.1364/OL.13.000186. PMID 19742022.
  16. ^ Gilgen HH, Novak RP, Salathe RP, Hodel W, Beaud P (1989). "Submillimeter optical reflectometry". Journal of Lightwave Technology. 7 (8): 1225–1233. Bibcode:1989JLwT....7.1225G. doi:10.1109/50.32387. ISSN 1558-2213.
  17. ^ Huang D, Wang J, Lin CP, Puliafito CA, Fujimoto JG (1991). "Micron-resolution ranging of cornea anterior chamber by optical reflectometry". Lasers in Surgery and Medicine. 11 (5): 419–425. doi:10.1002/lsm.1900110506. PMID 1816476. S2CID 19888483.
  18. ^ Hitzenberger CK (March 1991). "Optical measurement of the axial eye length by laser Doppler interferometry". Investigative Ophthalmology & Visual Science. 32 (3): 616–624. PMID 2001935.
  19. ^ a b Fercher AF (12–16 August 1990). "Ophthalmic interferometry". In von Bally G, Khanna S (eds.). Proceedings of the International Conference on Optics in Life Sciences. Garmisch-Partenkirchen, Germany. pp. 221–228. ISBN 0-444-89860-3.
  20. ^ a b Shinji Chiba; Naohiro Tanno (1991). Backscattering Optical Heterodyne Tomography. 14th Laser Sensing Symposium (in Japanese).
  21. ^ Fujimoto J, Swanson E (July 2016). "The Development, Commercialization, and Impact of Optical Coherence Tomography". Investigative Ophthalmology & Visual Science. 57 (9): OCT1–OCT13. doi:10.1167/iovs.16-19963. PMC 4968928. PMID 27409459.
  22. ^ Wijns W, Shite J, Jones MR, Lee SW, Price MJ, Fabbiocchi F, et al. (December 2015). "Optical coherence tomography imaging during percutaneous coronary intervention impacts physician decision-making: ILUMIEN I study". European Heart Journal. 36 (47): 3346–3355. doi:10.1093/eurheartj/ehv367. PMC 4677272. PMID 26242713.
  23. ^ Fujimoto J, Huang D (July 2016). "Foreword: 25 Years of Optical Coherence Tomography". Investigative Ophthalmology & Visual Science. 57 (9): OCTi–OCTii. doi:10.1167/iovs.16-20269. hdl:1721.1/105905. PMID 27419359.

and 27 Related for: Optical coherence tomography information

Request time (Page generated in 0.8168 seconds.)

Optical coherence tomography

Last Update:

Optical coherence tomography (OCT) is an imaging technique that uses interferometry with short-coherence-length light to obtain micrometer-level depth...

Word Count : 9559

Medical optical imaging

Last Update:

include optical microscopy, spectroscopy, endoscopy, scanning laser ophthalmoscopy, laser Doppler imaging, and optical coherence tomography. Because...

Word Count : 806

Tomography

Last Update:

higher computing cost. Although MRI (magnetic resonance imaging), optical coherence tomography and ultrasound are transmission methods, they typically do not...

Word Count : 1691

Spectroscopic optical coherence tomography

Last Update:

Spectroscopic optical coherence tomography (SOCT) is an optical imaging and sensing technique, which provides localized spectroscopic information of a...

Word Count : 1578

Intracoronary optical coherence tomography

Last Update:

Intracoronary optical coherence tomography (OCT) (or, more generally, intravascular optical coherence tomography) is a catheter-based imaging application...

Word Count : 2533

Optical coherence tomography angiography

Last Update:

Optical coherence tomography angiography (OCTA) is a non-invasive imaging technique based on optical coherence tomography (OCT) developed to visualize...

Word Count : 3129

Optical tomography

Last Update:

Optical tomography is a form of computed tomography that creates a digital volumetric model of an object by reconstructing images made from light transmitted...

Word Count : 686

Coherence length

Last Update:

In optical communications and optical coherence tomography (OCT), assuming that the source has a Gaussian emission spectrum, the roundtrip coherence length...

Word Count : 790

Quantum optical coherence tomography

Last Update:

Quantum optical coherence tomography (Q-OCT) is an imaging technique that uses nonclassical (quantum) light sources to generate high-resolution images...

Word Count : 1395

Interferometry

Last Update:

gating (optical coherence tomography) as well as phase-sensitive fluctuation spectroscopy to image subtle structural and dynamical properties. Optical coherence...

Word Count : 11100

Speckle variance optical coherence tomography

Last Update:

Speckle variance optical coherence tomography (SV-OCT) is an imaging algorithm for functional optical imaging. Optical coherence tomography is an imaging...

Word Count : 1616

Neurovascular unit

Last Update:

compared to microscopy techniques. Optical coherence tomography (OCT) is an imaging technique that utilizes low-coherence interferometry to generate high-resolution...

Word Count : 3756

Retina

Last Update:

retinal nerve cells, but in primates, this does not occur. Using optical coherence tomography (OCT), 18 layers can be identified in the retina. The layers...

Word Count : 9293

Doppler optical coherence tomography

Last Update:

Optical coherence tomography (OCT) is a technique that displays images of the tissue by using the backscattered light.[citation needed] Not only conserving...

Word Count : 1571

Optical heterodyne detection

Last Update:

interferometry and optical coherence tomography. Mutual coherence permits the rainbow in Newton's rings, and supernumerary rainbows. Consequently, optical heterodyne...

Word Count : 3644

Birefringence

Last Update:

living human thigh was measured using polarization-sensitive optical coherence tomography at 1310 nm and a single mode fiber in a needle. Skeletal muscle...

Word Count : 6582

Intravascular ultrasound

Last Update:

and other approaches. Fractional flow reserve Intracoronary Optical Coherence Tomography Hector M. Garcia-Garcia, Bill D. Gogas, Patrick W. Serruys &...

Word Count : 2464

Angiography

Last Update:

photographed. This test is often used to manage eye disorders. Optical coherence tomography (OCT) is a technology using near-infrared light to image the...

Word Count : 2057

Carmen Puliafito

Last Update:

orders on August 17, 2018. Puliafito was one of the inventors of optical coherence tomography; for this work, James Fujimoto, Eric Swanson and Puliafito received...

Word Count : 1157

Coherence scanning interferometry

Last Update:

Coherence scanning interferometry (CSI) is any of a class of optical surface measurement methods wherein the localization of interference fringes during...

Word Count : 634

Photoacoustic imaging

Last Update:

systems, photoacoustic/thermoacoustic computed tomography (also known as photoacoustic/thermoacoustic tomography, i.e., PAT/TAT) and photoacoustic microscopy...

Word Count : 1715

Ophthalmology

Last Update:

examination Dilated fundus examination Gonioscopy Refraction Optical coherence tomography (OCT) is a medical technological platform used to assess ocular...

Word Count : 5317

Optical projection tomography

Last Update:

Optical projection tomography is a form of tomography involving optical microscopy. The OPT technique is sometimes referred to as optical computed tomography...

Word Count : 563

Quantum imaging

Last Update:

assuring the measured light is from the material being studied. Optical coherence tomography uses Michelson interferometry with a distance adjustable mirror...

Word Count : 1996

Drusen

Last Update:

drusen and optic disc drusen can be observed by ophthalmoscopy. Optical coherence tomography scans of the orbits or head, calcification at the head of the...

Word Count : 1060

Glaucoma

Last Update:

measurement by using tonometry, anterior chamber angle assessment by optical coherence tomography, inspecting the drainage angle (gonioscopy), and retinal nerve...

Word Count : 11198

Optical coherence elastography

Last Update:

1950s. In 1998, Schmitt first proposed optical coherence elastography (OCE), in employing optical coherence tomography (OCT) detect depth-resolved sample...

Word Count : 2228

PDF Search Engine © AllGlobal.net