The saturated calomel electrode (SCE) is a reference electrode based on the reaction between elemental mercury and mercury(I) chloride. It has been widely replaced by the silver chloride electrode, however the calomel electrode has a reputation of being more robust. The aqueous phase in contact with the mercury and the mercury(I) chloride (Hg2Cl2, "calomel") is a saturated solution of potassium chloride in water. The electrode is normally linked via a porous frit (sometimes coupled to a salt bridge) to the solution in which the other electrode is immersed.
In cell notation the electrode is written as:
and 16 Related for: Saturated calomel electrode information
The saturatedcalomelelectrode (SCE) is a reference electrode based on the reaction between elemental mercury and mercury(I) chloride. It has been widely...
reasons it has widely replaced the saturatedcalomelelectrode. For example, it is usually the internal reference electrode in pH meters and it is often used...
electrode (RHE) (E = 0.000 V - 0.0591 × pH) at 25 °C Saturatedcalomelelectrode (SCE) (E = +0.241 V saturated) Copper–copper(II) sulfate electrode (CSE)...
interface between metallic mercury and a chloride solution in a saturatedcalomelelectrode, which is used in electrochemistry to measure pH and electrical...
channel regions as the gate length increases Saturatedcalomelelectrode, a commonly used reference electrode used in pH measurement and general aqueous...
ion is reduced at a potential of -0.60 V (relative to the saturated calomelelectrode), while zinc ions are not; this allows the determination of lead in...
close to ESCE= -400 mV (the potential refers to the standard Saturatedcalomelelectrode (SCE), depending on the alloy composition, electroplated zinc...
undergoes a one-electron oxidation at around 0.4 V versus a saturatedcalomelelectrode (SCE), becoming ferrocenium. This reversible oxidation has been...
centrifuge, substances of different densities separate. pH meter Saturatedcalomelelectrode Hygrometer the density of water in air Lysimeter the balance...
complex references such as standard hydrogen electrode, saturatedcalomelelectrode, or silver chloride electrode(specific concentration) can not directly...
one-electron reduction in the range of -0.7 to -0.9V versus the saturatedcalomelelectrode. They observed that clusters with more electronegative substituents...
laboratory use. Therefore, other more stable reference electrodes such as silver chloride and saturatedcalomel (SCE) are commonly used because of their more reliable...
unipositive cation. The following data are presented relative to the saturatedcalomelelectrode (SCE) in acetonitrile: [Fe(C5H5)2]+ / [Fe(C5H5)2] +0.38 V [Co(C5H5)2]+...
the WE and a reference electrode RE (saturatedcalomel, Ag/AgCl). The current is measured between the WE and the counter electrode CE (carbon vitreous,...