Global Information Lookup Global Information

Saturated calomel electrode information


The saturated calomel electrode (SCE) is a reference electrode based on the reaction between elemental mercury and mercury(I) chloride. It has been widely replaced by the silver chloride electrode, however the calomel electrode has a reputation of being more robust. The aqueous phase in contact with the mercury and the mercury(I) chloride (Hg2Cl2, "calomel") is a saturated solution of potassium chloride in water. The electrode is normally linked via a porous frit (sometimes coupled to a salt bridge) to the solution in which the other electrode is immersed.

In cell notation the electrode is written as:

and 16 Related for: Saturated calomel electrode information

Request time (Page generated in 0.7829 seconds.)

Saturated calomel electrode

Last Update:

The saturated calomel electrode (SCE) is a reference electrode based on the reaction between elemental mercury and mercury(I) chloride. It has been widely...

Word Count : 1218

Silver chloride electrode

Last Update:

reasons it has widely replaced the saturated calomel electrode. For example, it is usually the internal reference electrode in pH meters and it is often used...

Word Count : 2046

Reference electrode

Last Update:

electrode (RHE) (E = 0.000 V - 0.0591 × pH) at 25 °C Saturated calomel electrode (SCE) (E = +0.241 V saturated) Copper–copper(II) sulfate electrode (CSE)...

Word Count : 1276

Calomel

Last Update:

interface between metallic mercury and a chloride solution in a saturated calomel electrode, which is used in electrochemistry to measure pH and electrical...

Word Count : 1958

PH meter

Last Update:

Antimony electrode Ion-selective electrodes ISFET pH electrode Potentiometry Quinhydrone electrode Saturated calomel electrode Silver chloride electrode Standard...

Word Count : 2972

ISFET

Last Update:

meter Potentiometry Quinhydrone electrode Saturated calomel electrode Silver chloride electrode Standard hydrogen electrode Bergveld, Piet (October 1985)...

Word Count : 2278

SCE

Last Update:

channel regions as the gate length increases Saturated calomel electrode, a commonly used reference electrode used in pH measurement and general aqueous...

Word Count : 353

Amperometric titration

Last Update:

ion is reduced at a potential of -0.60 V (relative to the saturated calomel electrode), while zinc ions are not; this allows the determination of lead in...

Word Count : 628

Electrogalvanization

Last Update:

close to ESCE= -400 mV (the potential refers to the standard Saturated calomel electrode (SCE), depending on the alloy composition, electroplated zinc...

Word Count : 1974

Ferrocene

Last Update:

undergoes a one-electron oxidation at around 0.4 V versus a saturated calomel electrode (SCE), becoming ferrocenium. This reversible oxidation has been...

Word Count : 5131

List of measuring instruments

Last Update:

centrifuge, substances of different densities separate. pH meter Saturated calomel electrode Hygrometer the density of water in air Lysimeter the balance...

Word Count : 3618

Bulk electrolysis

Last Update:

complex references such as standard hydrogen electrode, saturated calomel electrode, or silver chloride electrode(specific concentration) can not directly...

Word Count : 1247

Methylidynetricobaltnonacarbonyl

Last Update:

one-electron reduction in the range of -0.7 to -0.9V versus the saturated calomel electrode. They observed that clusters with more electronegative substituents...

Word Count : 2041

Reduction potential

Last Update:

laboratory use. Therefore, other more stable reference electrodes such as silver chloride and saturated calomel (SCE) are commonly used because of their more reliable...

Word Count : 3173

Rhodocene

Last Update:

unipositive cation. The following data are presented relative to the saturated calomel electrode (SCE) in acetonitrile: [Fe(C5H5)2]+ / [Fe(C5H5)2] +0.38 V [Co(C5H5)2]+...

Word Count : 7213

Photoelectrochemistry

Last Update:

the WE and a reference electrode RE (saturated calomel, Ag/AgCl). The current is measured between the WE and the counter electrode CE (carbon vitreous,...

Word Count : 1073

PDF Search Engine © AllGlobal.net