Focused impedance measurement
Purpose
quantifying the electrical resistance in tissues
Focused Impedance Measurement (FIM) is a recent technique for quantifying the electrical resistance in tissues of the human body with improved zone localization compared to conventional methods. This method was proposed and developed by Department of Biomedical Physics and Technology of University of Dhaka under the supervision of Prof. Khondkar Siddique-e-Rabbani;[1][2] who first introduced the idea. FIM can be considered a bridge between Four Electrode Impedance Measurement (FEIM) and Electrical impedance Tomography (EIT), and provides a middle ground in terms of simplicity and accuracy.
Many biological parameters and processes can be detected and monitored through their effects on bioimpedance. Bioimpedance measurement can be performed with a few simple instruments and non-invasively.
Measurement of electrical impedance to obtain physiological or diagnostic information has been of interest to researchers for many years. However, the human body is geometrically and conductively uneven, with variation between individuals and phases of normal body activity, and bioimpedance results from many factors, including ion concentrations, cell geometry, extra-cellular fluids, intra-cellular fluids, and organ geometry. This makes accurate analysis of results from a small number of electrodes difficult and unreliable. Identifying zones with specific impedances can provide greater certainty regarding the factors behind the impedance.
Conventional Four Electrode or Tetra-polar Impedance Measurement (TPIM) is simple, but the zone of sensitivity is not well defined and may include organs other that those of interest, making interpretation difficult and unreliable. On the other hand, Electrical impedance tomography (EIT) offers reasonable resolution, but is complex and require many electrodes. By placing two FEIM systems perpendicular to each other over a common zone at the center and combining the results,[3] it is possible to obtain enhanced sensitivity over this central zone. This is the basis of FIM, which may be useful for impedance measurements of large organs like stomach, heart, and lungs. Being much simpler in comparison to EIT, multifrequency systems can be simply built for FIM.
FIM may be useful in other fields where impedance measurements are performed, like geology.
^K S Rabbani; M Sarker; M H R Akond; T Akter (1999). "Focused Impedance Measurement (FIM): A New Technique with Improved Zone Localization". Annals of the New York Academy of Sciences. 873 (1): 408–420. Bibcode:1999NYASA.873..408R. doi:10.1111/j.1749-6632.1999.tb09490.x. PMID 10372184. S2CID 80628.
^BAS Gold Medal Award Ceremony 2011 Archived 2013-07-29 at the Wayback Machine, Bangladesh Academy of Sciences
^Ferdous, Humaya; Tanvir Noor Baig; K. Siddique-e Rabbani (28 December 2013). "Thorax mapping for localized lung impedance change using focused impedance measurement (FIM): A pilot study". Electrical Bioimpedance. 4: 57–61. doi:10.5617/jeb.778. S2CID 55005285. Retrieved 14 February 2014.
and 27 Related for: Focused impedance measurement information
FocusedImpedanceMeasurement (FIM) is a recent technique for quantifying the electrical resistance in tissues of the human body with improved zone localization...
Electrical impedance tomography (EIT) is a noninvasive type of medical imaging in which the electrical conductivity, permittivity, and impedance of a part...
with impedances with non-negative resistive components, our interest is focused on the area inside the circle. The transformation, for an impedance Smith...
called impedance bridging. In this configuration the output impedance of the microphone should be negligible in comparison with the input impedance of the...
their so-called characteristic impedance. At the proximal aortic site, the 3-element Windkessel model of this impedance can be modelled with sufficient...
the light beam for sensing. The measuring system commonly uses measurement of impedance (or conductivity) and optical systems – lamps (mercury, xenon);...
medicine Sono arsenic filter was invented by Abul Hussam in 2006 FocusedImpedanceMeasurement by Khondkar Siddique-e-Rabbani Fingerprint Identification by...
Electrical impedance myography, or EIM, is a non-invasive technique for the assessment of muscle health that is based on the measurement of the electrical...
are proportional to each other at a ratio defined by the characteristic impedance of the medium through which the wave is propagating. In contrast, the...
instrument and typically has a resistor of ten times the oscilloscope's input impedance. This results in a 0.1 (‑10×) attenuation factor; this helps to isolate...
currents and the impedance of that conductor. This is of particular importance with some types of telecommunication and measurement equipment. In TT systems...
vacuum wave impedance to the wave impedance of the medium. The reflectivity R0 between two media can thus be expressed both by the wave impedances and the...
have lower input impedances, as low as 15 kΩ. Since it is possible to use high output impedance devices due to the high input impedance, other factors may...
units), or exactly 1 (in Gaussian units). The characteristic impedance (η) equals the impedance of free space Z0 ≈ 376.73 Ω. The vacuum of classical electromagnetism...
but will be insensitive because it is designed to match the acoustic impedance of water, a denser fluid than air. Sound travels 4.3 times faster in water...
generated by the acoustic impedance (Z) contrast between two materials. Scanning acoustic microscopy works by directing focused sound from a transducer...
ringing) at various frequencies; impedance vs. frequency; and small-signal vs. large-signal performance. Most of these measurements require sophisticated and...
ideal location for pH measurement to confirm the diagnosis of the laryngopharyngeal reflux is the pharynx and new studies have focused on the development...
interact with any electrical impedance in the walls of the beam pipe. This may be in the form of a resistive impedance (i.e., the finite resistivity...
(ninth ed.). New York: McGraw-Hill. pp. 267–9. ISBN 978-0-07-285293-6. "Impedance Audiometry". MedScape. 2018-09-12. W. Niemeyer (1971). "Relations between...
Wallace H. Coulter in 1953. The Coulter principle uses electrical impedancemeasurements to count blood cells and determine their sizes; it is a technology...
network, to achieve in-phase operation and impedance matching to the amplifier. The reverberation-time measurements are often used to calculate wall/partition...
can be measured including impedance, admittance, modulus, and permittivity (dielectric constant and loss). Complex impedance spectroscopy has also been...
\rho \,} from the above formula is known as the characteristic acoustic impedance. The acoustic power (energy per second) crossing unit area is known as...