A Stockbridge damper is a tuned mass damper used to suppress wind-induced vibrations on slender structures such as overhead power lines,[1] long cantilevered signs[2] and cable-stayed bridges. The dumbbell-shaped device consists of two masses at the ends of a short length of cable or flexible rod, which is clamped at its middle to the main cable. The damper is designed to dissipate the energy of oscillations in the main cable to an acceptable level.[3]

An example photo of Stockbridge dampers hanging under-slung from high voltage wires
Stockbridge dampers installed on high voltage power lines
  1. ^ Markiewicz, M. (29 November 1995), "Optimum dynamic characteristics of Stockbridge dampers for dead-end spans", Journal of Sound and Vibration, 188 (2): 243–256, Bibcode:1995JSV...188..243M, doi:10.1006/jsvi.1995.0589
  2. ^ Cite error: The named reference DOT was invoked but never defined (see the help page).
  3. ^ Kiessling, Friedrich; Nefzger, Peter; Nolasco, Joao F.; Kaintzyk, Ulf (2003), Overhead Power Lines, Springer, pp. 311–312, ISBN 3-540-00297-9

and 14 Related for: Stockbridge damper information

Request time (Page generated in 0.7894 seconds.)

Stockbridge damper

Last Update:

A Stockbridge damper is a tuned mass damper used to suppress wind-induced vibrations on slender structures such as overhead power lines, long cantilevered...

Word Count : 957

Damper

Last Update:

various brass instruments Damper (flow), a mechanical device in a duct or chimney that regulates airflow Stockbridge damper, used to suppress wind-induced...

Word Count : 191

Tuned mass damper

Last Update:

A tuned mass damper (TMD), also known as a harmonic absorber or seismic damper, is a device mounted in structures to reduce mechanical vibrations, consisting...

Word Count : 2742

Inertia damper

Last Update:

There are many types of physical devices that can act as inertia dampers: Stockbridge damper - absorbs resonant wave motions in wire and support cables, seen...

Word Count : 417

Stockbridge

Last Update:

Stockbridge may refer to: Stockbridge, Edinburgh, a district of Edinburgh, Scotland Stockbridge, Hampshire Stockbridge, West Sussex Stockbridge Anticline...

Word Count : 332

Transmission tower

Last Update:

maximised which reduces the chance of a leakage in moist conditions. Stockbridge dampers are added to the transmission lines a meter or two from the tower...

Word Count : 4998

Overhead power line

Last Update:

power lines can suffer from aeroelastic flutter driven by wind, Stockbridge dampers are often attached to the lines to reduce the vibrations. A compact...

Word Count : 4660

List of inventions named after people

Last Update:

Chapman Stillson Stirling engine – Rev. Robert Stirling Stockbridge damper – George H. Stockbridge Stokes mortar – Wilfred Stokes Strowger switch – Almon...

Word Count : 1828

Vortex shedding

Last Update:

cylinder diameter. A tuned mass damper can be used to mitigate vortex shedding in stacks and chimneys. A Stockbridge damper is used to mitigate aeolian vibrations...

Word Count : 801

Conductor gallop

Last Update:

flutter, transmission lines may be fitted with tuned mass dampers (known as Stockbridge dampers) clamped to the wires close to the towers. The use of bundle...

Word Count : 1124

Philip Dulhunty

Last Update:

spending 10 hours on a train journey. Stockbridge dampers, invented and patented in the 1920s by George H. Stockbridge, an engineer for Southern California...

Word Count : 1297

Severn Bridge

Last Update:

this offers is an attempt to reduce vibration, as is the use of Stockbridge dampers on the cables. The bridge is 5,240 ft (1,600 m) long, consisting...

Word Count : 3683

Buddleja farreri

Last Update:

ample flannely foliage", however Bean noted that it is probably the cooler, damper UK climate which prevents the shrub from making the striking display that...

Word Count : 487

List of IEC standards

Last Update:

IEC 61897 Overhead lines – Requirements and tests for Stockbridge type aeolian vibration dampers IEC TR 61901 Development tests recommended on cables with...

Word Count : 17123

PDF Search Engine © AllGlobal.net