The multislice algorithm[1] is a method for the simulation of the elastic scattering of an electron beam with matter, including all multiple scattering effects. The method is reviewed in the book by John M. Cowley,[2] and also the work by Ishizuka.[3] The algorithm is used in the simulation of high resolution transmission electron microscopy (HREM) micrographs, and serves as a useful tool for analyzing experimental images.[4] This article describes some relevant background information, the theoretical basis of the technique, approximations used, and several software packages that implement this technique. Some of the advantages and limitations of the technique and important considerations that need to be taken into account are described.
^Cite error: The named reference Cowley was invoked but never defined (see the help page).
^John M. Cowley (1995). Diffraction Physics, 3rd Ed. North Holland Publishing Company.
The multislice algorithm is a method for the simulation of the elastic scattering of an electron beam with matter, including all multiple scattering effects...
Kenneth A., et al. (11 September 2000). "Musculoskeletal Imaging with Multislice CT". American Journal of Roentgenology. 176 (4): 979–986. doi:10.2214/ajr...
baggage, vehicles and individuals have many applications. Tools like multislice helical computed tomography can be used for detailed documentation of...
gray values of cone-beam computed tomography with hounsfield units of multislice computed tomography: An in vitro study". Indian Journal of Dental Research...
an enhancement of at least 30 HU for proper evaluation according to: Multislice CT (3 ed.). Springer-Verlag Berlin and Heidelberg GmbH & Co. KG. 2010...
to obstruction by a clot). This type of examination is as accurate as multislice CT, but is less used, due to the greater availability of CT technology...
require extensive computer simulation and analysis, such as electron multislice analysis. More complex behavior in the diffraction plane is also possible...
to 2023 have been: Fast numerical methods based upon the Cowley-Moodie multislice algorithm, which only became possible once the fast Fourier transform...
anticoagulation to cardiac valvular and coronary calcium assessed by multislice spiral computed tomography". The American Journal of Cardiology. 96 (6):...
unique trauma post-anesthesia care unit, in addition to two dedicated multislice CT scanners, an angiography suite, and digital plain film capability....
Deborah; Patino, Cesar; Nelson, Thomas R.; Pretorius, Dolores H. (2008). Multislice Display of the Fetal Face Using 3‐Dimensional Ultrasonography. Journal...
Hassan Gamal Abd El Nasser; Taymour, Takeya Ahmed (2018-12-01). "Role of multislice computed tomography in evaluation of congenital tracheobronchial branching...
London ("the City") NUMIS (Northwestern University Multislice and Imaging System), see Multislice "Numi Numi", a 2004 artwork by Shuli Nachshon Numi-Torem...
GIMIAS GIMIAS GUI includes multislice view of multimodal biomedical images and signal navigation tools Stable release 1.5.r4 / October 2012; 11 years ago (2012-10)...
Gastrointestinal Tract: edited by Jaap Stoker (listed as a contributor). Multislice CT: edited by Konstantin Nikolaou, Fabian Bamberg, Andrea Laghi, Geoffrey...
that of a multislice CT scanner, with resolution ranges between 200 and 300 μm in high-resolution mode, compared to up to 600μm for a multislice CT. Contrast...
postmortem examination of the body" that is done in a conventional autopsy; Multislice spiral CT and MRI for visualising the body in 3D. This supplements the...
example). To cope with this complexity methods based upon the Cowley-Moodie multislice algorithm and non-linear imaging theory have been developed to simulate...
making it unsuitable for some scanning requirements. This method is a multislice B1 mapping technique. DREAM can be used to acquire a 2D B1 map in 130...
4 of reference. Only by considering the full dynamical model through multislice calculations can the diffraction patterns generated by PED be simulated...
hindrance of surgical revascularization, and impairment of imaging with multislice CT. To overcome some of these potential drawbacks, several companies are...
(single-slice CT) or the total thickness of all simultaneously acquired slices (multislice CT). The following quantity is therefore used to take account of pitch:...