Testing of floor surfaces for slip resistance relating to slip and fall hazards.
Floor slip resistance testing is the science of measuring the coefficient of friction (or resistance to slip accidents) of flooring surfaces, either in a laboratory (before or after installation) or on floors in situ. Slip resistance testing (or floor friction testing) is usually desired by the building's owner or manager when there has been a report of a slip and fall accident, when there has been a report of a near accident, or (preferably) before the flooring is installed on the property. Flooring is tested using a tribometer (floor slip resistance tester) to discover if there is a high propensity for slip and fall accidents on it, either dry and/or (most often) when wet with water or lubricated with other contaminants such as kitchen grease, hydraulic oil, etc. There have been numerous floor slip resistance testing tribometers and lab devices produced around the world to measure both the static (stationary) and dynamic (in motion) coefficient of friction, but presently there are only a few that have been proven to be reliable for obtaining useful safety results and that have current official test methods. Static coefficient of friction (SCOF) testing has always been unreliable for assessing safety in the wet condition, so any reliable slip resistance test will be measuring the available slip resistance to someone who is moving (dynamic) across the floor, and therefore will be assessing dynamic coefficient of friction (DCOF). If an instrument has no official published test method, or has a withdrawn (or historical) test method, then there is a problem with the instrument, often being poor precision.
To assess a floor's slip resistance, a reliable, thoroughly researched (in interlaboratory studies) floor friction test method must be used, and then a minimum safety criterion (0.42, 0.60, 36, etc.) is needed to apply to the results. Each different slip test device will have its own safety criterion. If the floor is likely to be lubricated with water or grease in use, it needs to be anti-slip under these expected conditions. Floor slip resistance testing can be carried out dry, wet with water, or lubricated with oils and other contaminants. Dry slip resistance is not an indicator of wet slip resistance — in fact the two often vary inversely — so reliable wet slip resistance testing is often needed as well as reliable dry testing.
and 25 Related for: Floor slip resistance testing information
Floorslipresistancetesting is the science of measuring the coefficient of friction (or resistance to slip accidents) of flooring surfaces, either in...
Sustainable SlipResistance is a particular floor friction testing method and selection criteria for use in choosing and sourcing slip-resistant flooring...
traction. Reliable, science-backed floorslipresistancetesting can help floor owners and designers determine if their floor is too slippery, or allow them...
order to develop health and safety standards. Floorslipresistancetesting Ice cleats, used to prevent slipping when walking on icy roads Wen-Ruey Chang,...
Ultra-durable, water-based polyurethane makes an excellent coating for adding slipresistance, beautiful appearance, and protection from penetrating stains. Look...
clogs. Slip-joint fittings are frequently used in kitchen, bathroom and tub drainage systems. They include a detached (movable) slip nut and slip-joint...
more than 12%. SRA/SRB/SRC – Slip-resistance of sole: Three tests make up the one rating for slipresistance. Each test is done with a mechanical heel...
but the glass slipped out of the tongs and fell to the floor. The thing bounced and didn't break. It sounded like steel hitting the floor. ... WKI Holding...
National Standards Institute) Standard for testing guardrails. Steel guardrail system manufacturers test their systems to withstand impacts from a 10...
has it become possible to perform 1:1 scale testing on full structures. Due to the costly nature of such tests, they tend to be used mainly for understanding...
150-mile (240 km) range was tested on public roads in early 2021, starting in Los Angeles and San Francisco. By April 2021, testing had expanded to Denver...
shift points as well as the speed of the shifts (amount of transmission slip between shifts). Factory Mode, Economy/Touring Mode and Sport Mode. Economy...
needs to be tested regularly to ensure it is still protecting the worker. Because of the high risk involved in this trade, this testing needs to be performed...
shaping by hand (sometimes including a rotation process called "throwing"), slip casting, tape casting (used for making very thin ceramic capacitors), injection...
Slip Sheets, and Other Bases for Unit Loads, by the American National Standards Institute (ANSI), at Material Handling Institute ASTM D 1185 Test Methods...
December 2022. "ASTM C39 Concrete Cylinder Compression Testing". admet.com. American Society for Testing and Materials. Retrieved 12 December 2022. Jipa, Andrei;...
Laboratory facilities capable of the required control tests, many being certified for specific testing in accordance with National Standards. Equipment with...
Nambu charges its head, Dr. Komibe, with the testing of whether a space capsule is fireproof or not, a test which requires the highly powerful incinerator...
tuning. The RS version was released with a mechanical plate type rear limited-slip differential (LSD). The GSR came with all of the conveniences of a typical...
five-speed ZF manual transmission. It had an aluminium body, a Salisbury limited-slip differential, four-wheel independent suspension, and vacuum servo-assisted...
sets, the transmission progressively sends power to the rear wheels. Under slip conditions, it can achieve an equal split in front and rear axle speeds....
included off-road under-body skid-plate protection, Traction-Lok rear limited-slip differential, and a heavy-duty trailer towing package. Optional was an electronically...
theoretically and then testing them, only to discover fundamental flaws, rapid prototypes allow for comparatively quick development and testing, shortening the...
rises to that of a 'low speed' test.[citation needed] In systems with significant non-uniform stress fields, because local slip occurs before the system slides...
Minehiro (2018). "Idealization of bond stress-slip relationship at elevated temperatures based on pullout tests". ACI Structural Journal. 115 (2). doi:10...