Global Information Lookup Global Information

Fire detection information


Fire detectors sense one or more of the products or phenomena resulting from fire, such as smoke, heat, infrared and/or ultraviolet light radiation, or gas.

In dwellings, smoke detectors are often stand-alone devices. In non-domestic buildings, fire detection will typically take the form of a fire alarm system, incorporating one or more of the following automatic devices:

  • Heat detector
  • Smoke detector
  • Flame detector
  • Fire gas detector

and 28 Related for: Fire detection information

Request time (Page generated in 0.7998 seconds.)

Fire detection

Last Update:

stand-alone devices. In non-domestic buildings, fire detection will typically take the form of a fire alarm system, incorporating one or more of the following...

Word Count : 69

Fire alarm system

Last Update:

and performance criteria for fire detection control and indicating equipment utilised in building fire detection and fire alarm systems: Australia AS 1603...

Word Count : 3273

Wildfire

Last Update:

bushfire (in Australia), desert fire, grass fire, hill fire, peat fire, prairie fire, vegetation fire, or veld fire. Some natural forest ecosystems depend...

Word Count : 19356

Linear heat detection

Last Update:

detection (LHD) (also known as linear detection wire or linear heat detection cable or linear heat) is a very commonly used method of fire detection....

Word Count : 205

BACnet

Last Update:

air-conditioning control (HVAC), lighting control, access control, and fire detection systems and their associated equipment. The BACnet protocol provides...

Word Count : 1147

Automatic fire suppression

Last Update:

water mist or the use of early warning smoke detection systems. Fire Equipment Manufacturers Association: Fire Facts Archived February 17, 2016, at the Wayback...

Word Count : 990

Manual fire alarm activation

Last Update:

stations to be used in conjunction with automatic detection as part of the overall fire detection and alarm system. Systems in completed buildings tend...

Word Count : 1981

Optical beam smoke detector

Last Update:

Maintenance of Fire Detection and Fire Alarm Systems - A Guide to BS Code 5839-1, London, United Kingdom: BSI, ISBN 978-0 580 63098 9 Fire Detection in Warehouse...

Word Count : 902

Flame detector

Last Update:

designed to detect and respond to the presence of a flame or fire, allowing flame detection. Responses to a detected flame depend on the installation, but...

Word Count : 3503

Active fire protection

Last Update:

and supplied by fire detection and control devices and are typically closed. ILDFA uses a dual approach, combining a water-based fire suppression system...

Word Count : 1484

Fire class

Last Update:

station. Sometimes fire blankets are used to stop a fire in a kitchen or on a stove. Fire control Fire extinguisher Fire Detection and Suppression Systems...

Word Count : 1341

Ansul

Last Update:

sophisticated fire detection/suppression systems, and a complete line of dry chemical, foam, and gaseous extinguishing agents. A common hand-held fire extinguisher...

Word Count : 2324

Wireless sensor network

Last Update:

vegetation. The early detection is crucial for a successful action of the firefighters; thanks to Wireless Sensor Networks, the fire brigade will be able...

Word Count : 6401

ISS ECLSS

Last Update:

life support system that provides or controls atmospheric pressure, fire detection and suppression, oxygen levels, waste management and water supply. The...

Word Count : 2279

Smoke detector

Last Update:

other large centres or institutions. Fire detection products have the European Standard EN 54 Fire Detection and Fire Alarm Systems that is a mandatory standard...

Word Count : 7434

Fire protection engineering

Last Update:

destructive effects of fire and smoke. It encompasses engineering which focuses on fire detection, suppression and mitigation and fire safety engineering...

Word Count : 2031

Fire lookout tower

Last Update:

radios. The promise of space satellite fire detection and modern cell phones tried to compete with the remaining fire lookout towers, but in several environments...

Word Count : 2905

Gaseous fire suppression

Last Update:

the agent, agent storage containers, agent release valves, fire detectors, fire detection system (wiring control panel, actuation signaling), agent delivery...

Word Count : 1046

Haze machine

Last Update:

type of fluid used. Because of this, haze is far less likely to set off fire alarms than fog machines or larger smoke particles. Theatrical smoke and...

Word Count : 688

BS 5839 Part 1

Last Update:

BS 5839 Part 1 Fire detection and fire alarm systems for buildings – Part 1: Code of practice for design, installation, commissioning and maintenance...

Word Count : 911

Nephelometer

Last Update:

susceptibility testing. Gas-phase nephelometers are also used in the detection of smoke and other particles of combustion. In such use, the apparatus...

Word Count : 1096

Ultraviolet

Last Update:

that will activate a UV detection system. The presence of UV-absorbing gases and vapors will attenuate the UV radiation from a fire, adversely affecting...

Word Count : 12375

EN 54

Last Update:

Fire detection and fire alarm systems is a series of European standards that includes product standards and application guidelines for fire detection...

Word Count : 925

Fire loading

Last Update:

measures, such as ensuring adequate fire detection and evacuation, or installation of a fire sprinkler system or other fire suppression system. v t e...

Word Count : 215

Amerex

Last Update:

military use. Other products include fire suppression systems for restaurants, gas detection systems, and fire detection devices. McWane, Inc. acquired Amerex...

Word Count : 345

Fire alarm notification appliance

Last Update:

A fire alarm notification appliance is an active fire protection component of a fire alarm system. A notification appliance may use audible, visible, or...

Word Count : 1778

Fire safety

Last Update:

portable fire extinguishers within a building, or may require permanently installed fire detection and suppression equipment such as a fire sprinkler...

Word Count : 2591

Fire alarm control panel

Last Update:

depleted. Fire alarm system Active fire protection EN 54 Fire detection and fire alarm systems in the EU. Burglary alarm "1.2 Features and Options". Fire Alarm...

Word Count : 3923

PDF Search Engine © AllGlobal.net