Electrospray (nanoSpray) ionization source

Electrospray ionization (ESI) is a technique used in mass spectrometry to produce ions using an electrospray in which a high voltage is applied to a liquid to create an aerosol. It is especially useful in producing ions from macromolecules because it overcomes the propensity of these molecules to fragment when ionized. ESI is different from other ionization processes (e.g. matrix-assisted laser desorption/ionization, MALDI) since it may produce multiple-charged ions, effectively extending the mass range of the analyser to accommodate the kDa-MDa orders of magnitude observed in proteins and their associated polypeptide fragments.[1][2]

Mass spectrometry using ESI is called electrospray ionization mass spectrometry (ESI-MS) or, less commonly, electrospray mass spectrometry (ES-MS). ESI is a so-called 'soft ionization' technique, since there is very little fragmentation. This can be advantageous in the sense that the molecular ion (or more accurately a pseudo molecular ion) is almost always observed, however very little structural information can be gained from the simple mass spectrum obtained. This disadvantage can be overcome by coupling ESI with tandem mass spectrometry (ESI-MS/MS). Another important advantage of ESI is that solution-phase information can be retained into the gas-phase.

The electrospray ionization technique was first reported by Masamichi Yamashita and John Fenn in 1984,[3] and independently by Lidia Gall and co-workers in Soviet Union, also in 1984.[4] Gall's work was not recognised or translated in the western scientific literature until a translation was published in 2008.[4] The development of electrospray ionization for the analysis of biological macromolecules[5] was rewarded with the attribution of the Nobel Prize in Chemistry to John Bennett Fenn and Koichi Tanaka in 2002.[6] One of the original instruments used by Fenn is on display at the Science History Institute in Philadelphia, Pennsylvania.

  1. ^ Ho, CS; Chan MHM; Cheung RCK; Law LK; Lit LCW; Ng KF; Suen MWM; Tai HL (February 2003). "Electrospray Ionisation Mass Spectrometry: Principles and Clinical Applications". Clin Biochem Rev. 24 (1): 3–12. PMC 1853331. PMID 18568044.
  2. ^ Pitt, James J (February 2009). "Principles and Applications of Liquid Chromatography-Mass Spectrometry in Clinical Biochemistry". Clin Biochem Rev. 30 (1): 19–34. PMC 2643089. PMID 19224008.
  3. ^ Yamashita, Masamichi; Fenn, John B. (September 1984). "Electrospray ion source. Another variation on the free-jet theme". The Journal of Physical Chemistry. 88 (20): 4451–4459. doi:10.1021/j150664a002.
  4. ^ a b Alexandrov, M. L.; Gall, L. N.; Krasnov, N. V.; Nikolaev, V. I.; Pavlenko, V. A.; Shkruov, V. A. (1984). "Extraction of ions from solutions under atmospheric pressure as a method for mass spectrometric analysis of bioorganic compounds". Doklady Akad. SSSR. 277 (3): 379–383. Bibcode:2008RCMS...22..267A. doi:10.1002/rcm.3113. PMID 18181250.
  5. ^ Fenn, J. B.; Mann, M.; Meng, C. K.; Wong, S. F.; Whitehouse, C. M. (1989). "Electrospray ionization for mass spectrometry of large biomolecules". Science. 246 (4926): 64–71. Bibcode:1989Sci...246...64F. CiteSeerX 10.1.1.522.9458. doi:10.1126/science.2675315. PMID 2675315.
  6. ^ Markides, K; Gräslund, A. "Advanced information on the Nobel Prize in Chemistry 2002" (PDF).

and 20 Related for: Electrospray ionization information

Request time (Page generated in 0.8007 seconds.)

Electrospray ionization

Last Update:

Electrospray ionization (ESI) is a technique used in mass spectrometry to produce ions using an electrospray in which a high voltage is applied to a liquid...

Word Count : 5340

Ion source

Last Update:

material into an electrospray source. Matrix-assisted laser desorption electrospray ionization (MALDESI) is an atmospheric pressure ionization source for generation...

Word Count : 7140

Ambient ionization

Last Update:

spectrometer. Desorption electrospray ionization (DESI) is one of the original ambient ionization sources and uses an electrospray source to create charged...

Word Count : 5967

Desorption electrospray ionization

Last Update:

Desorption electrospray ionization (DESI) is an ambient ionization technique that can be coupled to mass spectrometry (MS) for chemical analysis of samples...

Word Count : 3121

Secondary electrospray ionization

Last Update:

electro-spray ionization (SESI) is an ambient ionization technique for the analysis of trace concentrations of vapors, where a nano-electrospray produces charging...

Word Count : 2636

Mass spectrometry

Last Update:

development of electrospray ionization (ESI) and Koichi Tanaka for the development of soft laser desorption (SLD) and their application to the ionization of biological...

Word Count : 10342

Laser ablation electrospray ionization

Last Update:

Laser ablation electrospray ionization (LAESI) is an ambient ionization method for mass spectrometry that combines laser ablation from a mid-infrared (mid-IR)...

Word Count : 1879

Probe electrospray ionization

Last Update:

sample pick-up, initiating electrospray directly from the solid needle. Probe electrospray ionization is an ambient ionization mass spectrometry technique...

Word Count : 2229

Electrospray

Last Update:

Electric Fields, and Electrospray Ionization". Fundamental Studies of the Mechanisms and Applications of Field-Induced Droplet Ionization Mass Spectrometry...

Word Count : 1991

Sample preparation in mass spectrometry

Last Update:

desorption, electrospray ionization, and atmospheric-pressure chemical ionization. Both solid and liquid samples may be ionized with ambient ionization techniques...

Word Count : 5398

Nanospray desorption electrospray ionization

Last Update:

Nanospray desorption electrospray ionization (nano-DESI) is an ambient pressure ionization technique used in mass spectrometry (MS) for chemical analysis...

Word Count : 417

Extractive electrospray ionization

Last Update:

Extractive electrospray ionization (EESI) is a spray-type, ambient ionization source in mass spectrometry that uses two colliding aerosols, one of which...

Word Count : 1208

Lipidomics

Last Update:

Zheng; Cooks, R. Graham (2010-03-22). "Desorption electrospray ionization and other ambient ionization methods: current progress and preview". The Analyst...

Word Count : 4380

Protein mass spectrometry

Last Update:

used for the ionization of protein in mass spectrometry are electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI). These...

Word Count : 3815

Paper spray ionization

Last Update:

spray ionization is a technique used in mass spectrometry to produce ions from a sample to be analyzed. It is a variant of electrospray ionization. The...

Word Count : 329

Melamine

Last Update:

extraction (SPE) are often complex and time-consuming. However, electrospray ionization methods coupled with mass spectrometry allow a rapid and direct...

Word Count : 6424

Acetone peroxide

Last Update:

peroxide explosives by desorption electrospray ionization and desorption atmospheric pressure chemical ionization". Analytical Chemistry. 80 (5): 1512–9...

Word Count : 3810

Taylor cone

Last Update:

charged particles emanates above a threshold voltage. Aside from electrospray ionization in mass spectrometry, the Taylor cone is important in field-emission...

Word Count : 762

Ion beam deposition

Last Update:

evaporated solid, or a solution (liquid) are ionized. For atomic IBD, electron ionization, field ionization (Penning ion source) or cathodic arc sources...

Word Count : 562

Lidia Gall

Last Update:

Russian mass spectrometrist, credited as one of the inventors for electrospray ionization source and high-performance mass analyzers. Gall studied physical...

Word Count : 791

PDF Search Engine © AllGlobal.net